A compact terminal-type 0–15A AC/DC current transmitter delivering fast, precise low-current monitoring and seamless PLC integration in space-saving setups.
| Input Signal: | |
|---|---|
| Output Signal: | |
| Power Supply: | Please select |
| SKU: | |
| Availability: | |
| Quantity: | |
The QD-21 terminal current transmitter is specifically engineered for precise current sensing within the 0–15A range. This targeted capacity makes it highly suitable for low-current branches, light-load equipment circuits, and auxiliary power monitoring where standard high-current sensors often lack the necessary resolution. When monitoring small loads, using an oversized transmitter can lead to inaccu
n automated control systems, timing is a critical factor for operational stability. The QD-21 current transmitter features a fast response time of less than 100 milliseconds, ensuring that the monitoring system can accurately track rapid load start-stop events and sudden current fluctuations with minimal delay. Fast feedback is essential in low-current circuits, where brief operational changes might indicate a device switching state, a process transition, or an emerging abnormal load condition such as a motor jam or valve blockage.
Unlike traditional through-hole sensors that require cables to be threaded through a central aperture, the QD-21 utilizes IN+ and IN- terminals for direct current input. This design significantly reduces installation constraints related to wire thickness, bending radius, and limited cabinet space. The conductor can be wired straight into the transmitter alongside other DIN-rail or panel-mounted terminal devices, facilitating a highly compact and orderly control cabinet layout.
Working Principle Diagram
Signal Input Method:Terminal-wired design, directly inserted into the current loop under test
Compatible Input Types:Universal AC/DC signal acquisition
Standard Rated Range:DC: 0–1 A / 0–5 A / 0–10 A / 0–20 A / 0–50 A; AC: 0–1 A / 0–5 A / 0–10 A
Measurement Principle:High-precision sampling + optically isolated transmission
Compatible Signal Frequency:AC 45–400 Hz (power frequency / medium frequency); DC: no frequency limitation
Standard Transmitter Output Signal:4–20 mA, 0–20 mA, 0–5 V, 0–10 V; customizable 20–4 mA reverse output
Maximum Load Resistance for 4–20 mA Output:≤550 Ω
Minimum Load Impedance for Voltage Output:≥10 kΩ
Step Response Time (90% Steady-State Output):≤200 ms
Temperature Drift Coefficient Across Full Temperature Range:≤100 ppm/°C FS
Independent Linearity Error:±0.1% FS
Overall Accuracy of the Unit @ 25°C Ambient Temperature:Class 0.2 ±0.2% FS