| Input Signal: | Please select |
|---|---|
| Output Signal: | Please select |
| Channel : | Please select |
| Power: | Please select |
| SKU: | |
| Availability: | |
| Quantity: | |
QD-6024/6930 Intrinsically Safe Switching Output Isolator Barrier
QD-6024 / QD-6930 is a switching output safety barrier designed around “Integrated Control Function for Faster System Response.” Provides clear switching, alarm or relay functions for equipment control and interlocking. The alarm, relay, switching or control function turns the measured condition into a clear action for pumps, valves, warning devices or equipment interlocks. The feature is directly relevant to control cabinet, hazardous-area instrument loop and industrial process projects. Respond faster to abnormal conditions and equipment control demands, helping engineers keep the installation, inspection and signal path easier to manage during long-term operation.
QD-6024 / QD-6930 is a switching output safety barrier designed around “Direct Single-channel Switching Output Conversion.” Model options QD-6024, QD-6930 match different channel and point-count requirements. The channel and model arrangement makes it easier to match the number of field points without changing the overall cabinet architecture. The feature is directly relevant to control cabinet, hazardous-area instrument loop and industrial process projects. Handle more monitoring points with fewer separate cabinet modules, helping engineers keep the installation, inspection and signal path easier to manage during long-term operation.
QD-6024 / QD-6930 is a switching output safety barrier designed around “Intrinsically Safe Switching Output Isolation.” Separates the hazardous-area switching output loop from the safe-side control system. The isolated signal path separates the hazardous-area device from the safe-side control system and helps limit unwanted electrical interaction across the barrier. The feature is directly relevant to control cabinet, hazardous-area instrument loop and industrial process projects. Protect hazardous-area loops while keeping safe-side data stable, helping engineers keep the installation, inspection and signal path easier to manage during long-term operation.
Working Principle Diagram
On-State Output Accuracy:±0.5% FS @ 25℃ reference ambient
Load Regulation:< 0.1% FS across full allowable load range
Line Regulation:< 0.05% FS within 18~36 V DC supply range
Output Ripple & Noise:< 20 mVpp (on-state, full load condition)
Maximum Allowable Load Resistance:0 ~ 400 Ω (stable rated output maintained)
Off-State Leakage Current:< 0.1 mA, eliminates false triggering of downstream devices
Turn-on / Turn-off Response Time:< 2 ms (10% to 90% step change)
Input Switching Hysteresis:~10% of threshold, suppresses contact bounce & field noise interference
Output Short-Circuit Protection:Built-in self-recovering protection, automatic recovery after fault clearance
Common Mode Rejection Ratio (CMRR):≥ 120 dB @ 50/60 Hz
Normal Mode Rejection Ratio (NMRR):≥ 60 dB @ 50/60 Hz
Dimension Chart
Width x Height x Length: 17.7 mm x 110 mm x 118.9 mm
Wiring Diagram
content is empty!