WZPB 2088 Integrated Temperature Transmitter for Industrial Monitoring

WZPB is a 2088 integrated temperature transmitter combining temperature sensing, signal conversion and field display for industrial process monitoring and control.
Temperature Type:
Output Signal:
Probe Diameter:
Probe Length:
Connected:
Display Type:
SKU:
Availability:
Quantity:

WZPB 2088 Integrated Temperature Transmitter

WZPB intrinsically safe 2088 temperature transmitter for hazardous area temperature measurement

Intrinsically Safe Temperature Isolation

WZPB is a temperature transmitter designed around “Intrinsically Safe Temperature Isolation.” Separates the hazardous-area temperature loop from the safe-side control system. The isolated signal path separates the hazardous-area device from the safe-side control system and helps limit unwanted electrical interaction across the barrier. The feature is directly relevant to process pipeline, temperature monitoring and industrial process projects. Protect hazardous-area loops while keeping safe-side data stable, helping engineers keep the installation, inspection and signal path easier to manage during long-term operation.

WZPB 2088 industrial temperature transmitter with rugged field housing

2088 Industrial Housing for Demanding Installations

WZPB is a temperature transmitter designed around “2088 Industrial Housing for Demanding Installations.” The dedicated mechanical and connector structure simplifies installation, replacement and field maintenance. The dedicated mechanical, connector or mounting structure helps the instrument fit the intended pipe, tank, cabinet or equipment interface. The confirmed values highlighted here are 2088, 304. The feature is directly relevant to process pipeline, temperature monitoring and industrial process projects. Shorten installation time and simplify later field maintenance, helping engineers keep the installation, inspection and signal path easier to manage during long-term operation.

WZPB temperature transmitter with 4-20mA and RS485 for industrial control systems

Independent Dual Outputs for Control Systems

WZPB is a temperature transmitter designed around “Independent Dual Outputs for Control Systems.” Supports 4–20mA, RS485 for stable RS485 communication measurement and system integration. The standardized signal path routes the measured value to PLCs, DCS platforms, displays or remote monitoring equipment. The confirmed values highlighted here are 4–20mA, RS485. The feature is directly relevant to process pipeline, temperature monitoring and industrial process projects. Connect field measurements directly to existing plc and monitoring systems, helping engineers keep the installation, inspection and signal path easier to manage during long-term operation.

Working Principle Diagram

2088-温度传感器.jpg

Technical Specifications

Built-in Sensor Element:Pt100 platinum resistance thermometer (IEC 60751); optional K/E/J/T/S/B-type thermocouples

Accuracy Class:Pt100 sensor: Grade A; overall accuracy of the complete transmitter: ±0.2% FS; high-precision customization: ±0.1% FS

Standard Temperature Measurement Range:Pt100: -200°C to +400°C; Thermocouples: 0–800 °C; full range customizable

Pt100 Nominal Parameters:Resistance at 0 °C: 100.00 Ω; temperature coefficient α = 0.003851 Ω/°C

Standard Transmitter Output:4–20 mA; optional 0–5 V, 0–10 V, or reverse 20–4 mA

4–20 mA Maximum Load Resistance:≤550 Ω

Voltage Output Load Impedance:≥10 kΩ

Step Response Time τ0.9:≤12 s (flowing liquid medium)

Temperature Drift Coefficient Across Full Temperature Range:≤50 ppm/°C FS

Independent Linearity Error:±0.05% FS

Supply Voltage:12–36 V DC wide-range voltage, standard 24 VDC ±10%, two-wire power supply

Expanded Communication Options:Optional isolated RS485 Modbus-RTU digital output

Dimension Chart

image.png

Wiring Diagram

2088一体化温度传感器.jpg

Technical Specifications

Built-in Sensor Element:Pt100 platinum resistance thermometer (IEC 60751); optional K/E/J/T/S/B-type thermocouples


Accuracy Class:Pt100 sensor: Grade A; overall accuracy of the complete transmitter: ±0.2% FS; high-precision customization: ±0.1% FS


Standard Temperature Measurement Range:Pt100: -200°C to +400°C; Thermocouples: 0–800 °C; full range customizable


Pt100 Nominal Parameters:Resistance at 0 °C: 100.00 Ω; temperature coefficient α = 0.003851 Ω/°C


Standard Transmitter Output:4–20 mA; optional 0–5 V, 0–10 V, or reverse 20–4 mA


4–20 mA Maximum Load Resistance:≤550 Ω


Voltage Output Load Impedance:≥10 kΩ


Step Response Time τ0.9:≤12 s (flowing liquid medium)


Temperature Drift Coefficient Across Full Temperature Range:≤50 ppm/°C FS


Independent Linearity Error:±0.05% FS


Supply Voltage:12–36 V DC wide-range voltage, standard 24 VDC ±10%, two-wire power supply


Expanded Communication Options:Optional isolated RS485 Modbus-RTU digital output

Dimension Chart

image.png

Wiring Diagram

2088一体化温度传感器.jpg
微信图片_20260928101913_515_10.jpg
微信图片_20260928101917_516_10.jpg