JXK-7C is a hall current transmitter designed around “Large-aperture Design for Thick Conductors.” The dedicated mechanical and connector structure simplifies installation, replacement and field maintenance. The dedicated mechanical, connector or mounting structure helps the instrument fit the intended pipe, tank, cabinet or equipment interface. The feature is directly relevant to electrical monitoring, industrial process and automation system projects. Shorten installation time and simplify later field maintenance, helping engineers keep the installation, inspection and signal path easier to manage during long-term operation.
JXK-7C is a hall current transmitter designed around “Stable Ac/Dc Performance for Industrial Monitoring.” Supports 10–1200A, AC, DC for stable AC/DC measurement and system integration. The stated operating range, accuracy, response, overload or stability feature supports more dependable data under changing field conditions. The confirmed values highlighted here are 10–1200A, AC, DC. The feature is directly relevant to electrical monitoring, industrial process and automation system projects. Maintain clearer trend data during long-term industrial operation, helping engineers keep the installation, inspection and signal path easier to manage during long-term operation.
JXK-7C is a hall current transmitter designed around “Installation-focused Design for Hall Current Transmitter.” The dedicated mechanical and connector structure simplifies installation, replacement and field maintenance. The dedicated mechanical, connector or mounting structure helps the instrument fit the intended pipe, tank, cabinet or equipment interface. The feature is directly relevant to electrical monitoring, industrial process and automation system projects. Shorten installation time and simplify later field maintenance, helping engineers keep the installation, inspection and signal path easier to manage during long-term operation.
Working Principle Diagram
Compatible Input Types:Acquires all types of current: AC, DC, and pulse currents
Standard Rated Range:0–100 A / 0–200 A / 0–300 A / 0–500 A; supports customization of non-standard ranges
Detection Hole Diameter:Φ25mm standard aperture, compatible with single-strand power cables ≤25mm² Φ25mm/Φ38mm
Measurement Frequency Bandwidth:DC ~ 10kHz, covering DC, power-frequency, and medium-frequency pulse signals
Maximum Load Resistance for Output (4–20 mA):≤500Ω
Minimum Load Impedance for Voltage Output (0–5 V/0–10 V):≥10kΩ
Step Response Time:≤10μs, high-speed tracking of current transients
Temperature Drift Coefficient (Full Operating Temperature Range):≤150ppm/℃ FS
Independent Linearity Error:±0.2% FS
Overall Accuracy of the Unit @ 25°C Ambient Temperature:Standard Class 0.5 ±0.5% FS
Fault Output Characteristics:Overrange saturation output
Output Channel Configuration:Single-channel 1-in-1-out transmitter output,
Standard Transmitter Output Signal:4–20 mA, 0–20 mA, 0–5 V, 0–10 V, RS485, Relay. True RMS. Voltage follow.