QD-6045/6046/6049 4-20mA Intrinsically Safe Output Barrier
QD-6045 / QD-6046 / QD-6049 is a current output safety barrier designed around “Integrated Control Function for Faster System Response.” Provides clear switching, alarm or relay functions for equipment control and interlocking. The alarm, relay, switching or control function turns the measured condition into a clear action for pumps, valves, warning devices or equipment interlocks. The confirmed values highlighted here are 20mA, 4–20mA. The feature is directly relevant to control cabinet, hazardous-area instrument loop and industrial process projects. Respond faster to abnormal conditions and equipment control demands, helping engineers keep the installation, inspection and signal path easier to manage during long-term operation.
QD-6045 / QD-6046 / QD-6049 is a current output safety barrier designed around “Flexible Channel Options for Current Output Points.” Model options QD-6045, QD-6046, QD-6049 match different channel and point-count requirements. The channel and model arrangement makes it easier to match the number of field points without changing the overall cabinet architecture. The feature is directly relevant to control cabinet, hazardous-area instrument loop and industrial process projects. Handle more monitoring points with fewer separate cabinet modules, helping engineers keep the installation, inspection and signal path easier to manage during long-term operation.
QD-6045 / QD-6046 / QD-6049 is a current output safety barrier designed around “Intrinsically Safe Current Output Isolation.” Separates the hazardous-area current output loop from the safe-side control system. The isolated signal path separates the hazardous-area device from the safe-side control system and helps limit unwanted electrical interaction across the barrier. The feature is directly relevant to control cabinet, hazardous-area instrument loop and industrial process projects. Protect hazardous-area loops while keeping safe-side data stable, helping engineers keep the installation, inspection and signal path easier to manage during long-term operation.
Working Principle Diagram
Compatible Signal Type:4-20mA analog control signal
System Transmission Accuracy:±0.1% F.S., full-range temperature compensated
Temperature Drift Coefficient:≤30ppm/℃; minimal control deviation from seasonal ambient temperature changes
Non-linearity Error:≤0.05% F.S.
Step Response Time:≤100ms; follows rapid control setpoint changes without lag
Load Regulation:≤0.05% F.S. per 100Ω load change; stable output across varying field actuator input impedances
Power Supply Regulation:≤0.05% F.S. over full supply voltage range; immune to control room grid voltage fluctuations