BSR DIN Rail Temperature Transmitter for Automation

A DIN-rail PT100/Cu50 RTD temperature transmitter delivering accurate, standardized outputs for seamless PLC integration.

Input Signal:
Output Signal :
Channel:
Power Supply :
SKU:
Availability:
Quantity:

BSR DIN Rail RTD Temperature Transmitter

Dedicated PT100 and Cu50 RTD input temperature transmitter converting resistance temperature signals into standard outputs. Green DIN-rail mounted device with RTD sensor icons.

Dedicated PT100 / Cu50 RTD Input

The BSR DIN rail temperature transmitter is specifically engineered for PT100 and Cu50 resistance temperature detectors (RTDs). In industrial automation, accurately capturing temperature variations is critical for process control. By focusing exclusively on RTD inputs, this transmitter clearly separates resistance measurement from thermocouple applications, significantly reducing the risk of incorrect model selection during procurement and installation.

The module effectively measures the subtle resistance changes of the connected sensor and converts them into standardized, isolated analog signals that are directly compatible with PLCs, DCS systems, or local display instruments. This dedicated design not only provides a straightforward interface for common industrial temperature sensors but also ensures consistent cabinet wiring.

Linearized bridge compensation diagram showing active linearization of RTD resistance signals into linear standard signals. Features a green temperature transmitter with wiring guide.

Linearized Bridge Compensation

One of the inherent challenges with RTD sensors is their slight non-linear behavior across wide temperature ranges. The BSR temperature transmitter addresses this by incorporating advanced active linearized bridge compensation technology. Since an RTD output is a resistance value rather than a ready-to-use current or voltage signal, precise linearization is required before the receiving control system can interpret the temperature changes accurately.

The internal bridge-processing stage actively corrects the sensor's response curve, converting it into a highly consistent and proportional standard output across the entire selected measurement range. This critical feature provides the PLC or monitoring meter with a much clearer and more accurate temperature trend, significantly reducing signal distortion.

Multi-point RTD signal integration setup supporting 1-in/1-out, 1-in/2-out, and 2-in/2-out structures for centralized monitoring in a control cabinet.

Multi-point RTD Signal Integration

Modern control cabinets often face strict space limitations, making efficient signal integration essential. The BSR RTD temperature transmitter is available in versatile configurations, including 1-in/1-out, 1-in/2-out, and 2-in/2-out structures, designed specifically for centralized temperature monitoring. The 1-in/2-out model is particularly valuable when a single temperature measurement point needs to be shared simultaneously between two independent receiving devices, such as a main PLC and a local display meter, eliminating the need for an extra signal splitter.

Alternatively, the 2-in/2-out configuration allows two separate RTD inputs to be processed within a single, compact module housing. This high-density design drastically reduces the total number of individual converters required in multi-point control panels.

Working Principle Diagram

09d211d3892879c0d71a156e9e8ce6e7.jpg

Technical Specifications

Input Impedance (RTD):≥100 MΩ


Input Impedance (TC millivolt signal):≥20 MΩ


Maximum Output Load Resistance (4–20 mA):≤500 Ω


Voltage Output Load Impedance (0–5 V / 0–10 V):≥10 kΩ


Step Response Time (90% output stabilization):≤1000 ms


Temperature Drift Coefficient:75 ppm/°C FS


Independent Linearity Error:±0.1% FS


Overall Accuracy of the Unit @25°C:±0.2% FS


Field Calibration Method:Hardware DIP switch for range/scale selection; no adjustable potentiometers


Reverse Signal Output Support (20–4 mA / 0–10 V):Customizable


Two-Wire Sensor Power Supply:None


Open-Circuit Fault Diagnosis:NAMUR standard: <3.6 mA / >21 mA

Dimension Chart

1 In 1 Out: L*W*H: 114.5mm x 12.8mm x 99mm

1 In 3 Out: L*W*H: 114.5mm x 22.8mm x 99mm

image.png

Wiring Diagram

BSR-1.jpg
BSR-1.jpg
BSR-1.jpg
BSR-4.jpg
BSR-5.jpg
BSR-6.jpg
BSR-7.jpg
微信图片_20260928101913_515_10.jpg
微信图片_20260928101917_516_10.jpg
Previous: 
Next: 
Tel: +86-400-127-7889 / +86-561-3033839
Phone: +86-19715617532
Add: Building 14, University Science and Technology Park, Fenghuangshan Economic Development Zone, Xiangshan District, Huaibei City, Anhui Province

QUICK LINKS

PRODUCT CATEGORY

MORE LINKS

Copyright © 2026 Anhui Qidian Automation Technology Co., Ltd. All Rights Reserved.|Sitemap|Privacy Policy