| Range: | |
|---|---|
| Output Signal: | Please select |
| Power: | |
| Type: | |
| Connected: | |
| SKU: | |
| Availability: | |
| Quantity: | |
QDY70B Ultrasonic Level Meter
QDY70B measures liquid level from above the vessel using ultrasonic waves, so the sensor does not contact the medium. The transmitted sound pulse reflects from the liquid surface and returns to the instrument, allowing level to be calculated without a submerged probe. This approach reduces contamination between the sensor and the liquid and avoids corrosion or winding problems associated with contact devices. It is suitable for ordinary tanks, pools and water-storage applications that need a straightforward non-contact level signal.
The top-mounted design of QDY70B keeps the sensor accessible above the tank or pool. Routine inspection, wiring checks and replacement can be carried out from the mounting point without pulling a probe out of the liquid or handling a wet cable. This simplifies maintenance in applications where the vessel is deep or the liquid is inconvenient to contact. Easier access shortens service time, keeps the measuring point cleaner and supports more practical long-term use in standard level-monitoring projects.
QDY70B provides a cost-effective non-contact option for tanks, pools and general liquid-storage projects. It is intended for standard applications that do not require the more complex capabilities of high-frequency radar but still benefit from avoiding direct sensor contact with the medium. The simple top-mounted measuring method reduces installation and maintenance effort while supplying continuous level information to the monitoring system. This makes it a practical choice for budget-sensitive projects that need reliable everyday level indication and control.
Working Principle Diagram
Temperature Drift Coefficient:≤0.12% F.S./℃ within compensated range; eliminates seasonal measurement fluctuation
Blind Zone Performance:Minimum dead zone from 0.3m; reliable measurement close to tank top, reduces invalid measurement space
False Echo Suppression:Supports up to 16 sets of fixed false echo learning & storage; one-click on-site mapping for permanent obstacles
Measurement Repeatability:≤±2mm; consistent readings under stable operating conditions
Response Time:0.5 ~ 10s software adjustable; balances reading responsiveness and anti-interference stability
Relay Output (Advanced version):2-way SPDT relay, 5A @ 250VAC resistive load; independently configurable high/low level alarm & control hysteresis
On-board Fault Diagnosis:Multi-category fault code output; covers signal loss, over-range, sensor failure and temperature anomaly alarms
Automatic Gain Control:Dynamic signal gain adjustment; adapts to changing surface conditions without manual calibration
Dimension Chart
Wiring Diagram