The Three-Phase Digital Current/Voltage Panel Meter enables simultaneous A/B/C phase monitoring with full isolation and flexible communication for reliable, seamless PLC, HMI, and SCADA integration.
| Input Signal: | Please select |
|---|---|
| Output Signal: | |
| Connect: | Please select |
| Power: | |
| SKU: | |
| Availability: | |
| Quantity: | |
Three-Phase Digital Current Voltage Panel Meter
See All Three Phases at the Same TimeThree-phase current and voltage versions simultaneously acquire and display A, B and C phase values across three independent LED rows. Synchronized three-phase refresh makes phase-to-phase comparison more intuitive, helping operators identify abnormal differences during routine inspection without switching between individual readings. | |
Bring Three-Phase Data into Your Control SystemBeyond local three-phase indication, configurable versions support analog transmitter output, relay switching and RS485 Modbus-RTU communication. RS485 transmission can reach up to 1200m at 9600bps with shielded twisted-pair cable, making the meter suitable for integrating three-phase electrical data into remote monitoring and automation systems. | |
Keep Every Phase Stable and IndependentThe three-phase measurement architecture is designed to minimize interaction between channels, with inter-channel crosstalk below 0.01% FS. Three-way galvanic isolation separates the measurement input, auxiliary power and output/communication circuits, while 2000V AC RMS dielectric withstand and industrial EMC immunity support stable operation in electrically demanding cabinets. | |
Technical Specifications | |
Measurement Accuracy Class:0.2% FS ± 1 digit (reference condition: 25℃ ambient) Inter-phase Consistency Deviation:< 0.01% FS, ensures accurate 3-phase unbalance calculation Temperature Drift Coefficient:±50 ppm/℃ across full operating temperature range Non-linearity Error:< 0.1% FS (best fit straight line method) Sampling & Display Update Rate:3 times per second, synchronous refresh for all 3 phases Analog Transmitter Output Accuracy:±0.2% FS, with full temperature range automatic compensation Analog Output Load Capacity:0 ~ 500 Ω (current output type, supports long-distance transmission) Output Ripple Noise:< 10 mVpp Short-term Overload Capacity (Current Input):2× rated value for 10 s; 10× rated value for 1 s Short-term Overload Capacity (Voltage Input):1.2× rated value continuous; 2× rated value for 1 s Harmonic Suppression Capability:Up to 30th harmonic; measurement error < 0.2% under 10% THD grid Inter-channel Crosstalk:< 0.01% FS between all phases, no mutual interference Relay Output Contact Rating:SPST-NO, 3 A @ 250 V AC (resistive load) Relay Mechanical Endurance:≥ 10,000,000 operations (no-load condition) Relay Electrical Endurance:≥ 100,000 operations @ rated resistive load Communication Protocol:Standard Modbus-RTU via RS485 interface Baud Rate Range:1200 ~ 19200 bps, software configurable Maximum Communication Distance:1200 m @ 9600 bps (shielded twisted pair cable) Communication Bit Error Rate:≤ 10⁻¹² (full load, reference ambient condition) | |
Dimension Chart | ||
|