The Three-Phase Multifunction Power Meter delivers comprehensive, high-accuracy power monitoring with built-in harmonic analysis and flexible automation integration for reliable industrial power management.
| Input Signal: | Please select |
|---|---|
| Output Signal: | |
| Connect: | Please select |
| Power: | |
| SKU: | |
| Availability: | |
| Quantity: | |
Three-Phase Multifunction Power Meter
Monitor More Electrical Parameters with One MeterThe three-phase multifunction electrical meter integrates measurement of multiple electrical parameters into one compact panel instrument, including voltage, current, active and reactive power, active and reactive energy, power factor and frequency. This reduces the need for multiple dedicated meters and gives operators a more complete view of the distribution circuit from one display. | |
See More Than Voltage and CurrentBeyond standard voltage and current monitoring, the meter supports harmonic analysis from the 2nd to the 31st order together with voltage and current THD calculation. Synchronized three-phase measurement and low inter-phase deviation provide additional visibility into distribution-system operating conditions and phase imbalance. | |
Connect Power Data to Your Automation SystemThe multifunction meter supports RS485 Modbus-RTU communication for integration with industrial monitoring systems. Digital inputs, relay outputs, analog transmitter output and energy pulse functions extend the meter beyond local indication, allowing measured electrical data to support remote supervision, alarm logic and system-level energy management. | |
Technical Specifications | |
Active Power / Power Factor Accuracy:Class 0.5 Reactive Power Accuracy:Class 1.0 Active Energy Accuracy:Class 0.5S (compliant with IEC 62053-22) Reactive Energy Accuracy:Class 1 (compliant with IEC 62053-23) Frequency Measurement Range & Accuracy:45 ~ 65 Hz, ±0.01 Hz Harmonic Analysis Capability:2nd ~ 31st order harmonic; THD (Total Harmonic Distortion) calculation for voltage & current Temperature Drift Coefficient:±50 ppm/℃ across full operating temperature range Short-term Overload Capacity (Current):2× rated continuous; 10× rated for 1 second; 50× rated for 1 cycle Short-term Overload Capacity (Voltage):1.2× rated continuous; 2× rated for 1 second Inter-phase Consistency Deviation:< 0.05% FS, ensures accurate unbalance monitoring Energy Pulse Output:Passive photoelectric isolation output; 3200 imp/kWh (default, configurable) Digital Input (DI):4 channels, passive dry contact input, photoelectric isolation; debounce time configurable Relay Output (DO):SPST-NO, 3 A @ 250 VAC resistive load; supports upper/lower limit alarm Analog Transmitter Output Accuracy:±0.2% FS, 0~500 Ω load capacity (current output type) Communication Protocol & Interface:RS485 interface, standard Modbus-RTU protocol; 1200~19200 bps software configurable Maximum Communication Distance:1200 m @ 9600 bps (shielded twisted pair cable) Data Retention:Built-in non-volatile memory; energy & setting data stored > 10 years after power loss | |
Dimension Chart | ||
|